| 1 | P/W RR R SW UP | P/W RR R SW UP signal | With vehicle in ON mode and right rear power window moving to UP using power window master switch: about battery voltageIf none of above conditions are met: less than 0.2 V
 | 
| 2 | P/W RR R MTR UP | Drives right rear power window motor | With right rear power window moving to UP: about battery voltageIf none of above conditions are met: less than 0.2 V
 | 
| 3 | +B P/W RR R | Power source for right rear power window switch | With MICU is wakeup mode: about battery voltageWith MICU is sleep mode: less than 0.2 V
 | 
| 4 | P/W RR R SW DOWN | P/W RR R SW DOWN signal | With vehicle in ON mode and right rear power window moving to DOWN using power window master switch: about battery voltageIf none of above conditions are met: less than 0.2 V
 | 
| 5 | P/W RR R MTR DOWN | Drives right rear power window motor | With right rear power window moving to DOWN: about battery voltageIf none of above conditions are met: less than 0.2 V
 |